banner

Blog

Nov 11, 2024

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system | Nature Communications

Nature Communications volume 13, Article number: 5131 (2022) Cite this article

11k Accesses

40 Citations

49 Altmetric

Metrics details

The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δg/g = 2.0 × 10−6. This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

The growing importance of advanced sensing applications1,2,3,4,5,6,7,8,9,10 has inspired significant investment in quantum sensing technologies. One area of particular interest is the development of cold-atom inertial sensors based on a light-pulse atom interferometer (LPAI)11,12,13,14,15,16,17, using photon recoils from stimulated Raman transitions. The light pulse sequence of LPAIs, e.g., \(\frac{\pi }{2}\to T\to \pi \to T\to \frac{\pi }{2}\), coherently splits, redirects, and recombines atomic wavepackets for matter-wave interference, where T is the interrogation time. During this process, the phase shifts experienced by the atoms are sensitive to inertial forces, resulting in an atomic interference fringe that provides acceleration and angular velocity information.

Over the past 30 years18,19, LPAIs have demonstrated excellent laboratory sensitivity20, and serious efforts are underway to advance the platform for real-world applications21 and multi-axis sensors22,23,24,25. Their applications range from fundamental physics20,26,27,28,29 and geophysics30,31 to civil engineering32 and navigation33. Mobile LPAI prototypes have been demonstrated for land-based30,34, naval35, and airborne36,37,38 use under micro-g to <2 g environments, where g is the acceleration due to gravity. Furthermore, Bose-Einstein condensates have been tested under micro-g in sounding rockets39 and an Earth-orbiting research laboratory40 with the aim of demonstrating LPAI functionality. However, significant physics and engineering challenges currently hinder the development of deployable cold-atom inertial sensors in dynamic environments. For example, it is difficult to simultaneously ensure that the sensor maintains high performance in extreme dynamics and that the form factor of the sensor head and the laser system remains compact.

A trade-off arises in LPAI operation because the highest sensitivity is achieved with long-baseline atom interferometry (requiring a long T), but high dynamics can affect the relative movement between cold atoms and the interrogating laser beams (e.g., through on-axis acceleration, cross-axis acceleration, cross-axis rotation, and vibration) and therefore high data-rate LPAI operation is required to mitigate those effects (most effective with a short T). A short time-of-flight approach41,42,43 can produce an exceptional accelerometer that operates up to 330 Hz, opening up the possibility of LPAI operation in a high-g environment (e.g., 1.5 to 9 g44,45,46) with modest sensitivity towards high accelerometer performance (e.g., bias stability <0.5 μg, scale factor <1 ppm47).

To address these challenges, we present progress on a multifaceted approach. Our sensor head has a compact optomechanical design that includes fixed optical components, custom Ti vacuum packages, and microfabricated grating chips. Our laser system architecture is based on a single seed laser and multiple single sideband modulators (SSBMs) with time-multiplexed frequency shifting, which is compatible with (and, thus, can be replaced by) integrated photonic components. Using the sensor head and the laser system, we demonstrate a grating magneto-optical trap (GMOT)48,49,50,51,52,53,54,55,56 with a single laser-cooling beam, a high data-rate sub-Doppler-cooled GMOT (15 μK, 20 Hz), Ramsey interferometry with the GMOT, and an initial demonstration of a cold-atom accelerometer based on the GMOT (Δg/g = 2.0 × 10−6, T = 0 − 4.5 ms, 10 Hz). Our LPAI sensor head is designed to perform counter-propagating Doppler-sensitive Raman without a retroreflecting mirror. This is in contrast to most LPAI systems30,34,35,36,38, which rely on a retroreflecting mirror to maintain the phase between two Raman beams, an approach that makes it difficult to distinguish oppositely diffracted atoms57. Eliminating the retroreflecting mirror removes the degeneracy of low-velocity atoms present in retroreflecting Raman LPAIs57, enabling high data-rate operation.

To ensure that the LPAI can operate in high-dynamic conditions, the laser system must be designed to withstand such conditions since it is subjected to similar dynamics. Substantial efforts have been made towards the development of compact and robust laser systems58,59,60,61,62, including recent demonstrations with SSBMs63,64 and single seed lasers24,65,66,67. Many of these systems are based on discrete components with fiber-to-fiber connections or free-space optical path connections (with optomechanical alignment mounts), which limit their ability to withstand high dynamics and severely limit manufacturing scalability. Additive manufacturing68,69 may also provide pathways towards vacuum miniaturization and robust optics platforms.

To maximize manufacturability and performance with a small form-factor, we believe that microfabricated photonic integrated circuit (PIC) technology70,71,72,73,74,75,76,77 can be a robust and reliable solution. In another effort by our team, we have developed a PIC laser architecture to use a telecom wavelength (1560 nm) for light modulation and optical amplification and use a frequency-doubled wavelength (780 nm) to address Rb atoms; we have performed demonstrations of critical PIC components70.

In this paper, we demonstrate a laser system with similar architecture to the PIC-based concept using commercial-off-the-shelf (COTS) components. The combination of our PIC-compatible approach and our high data-rate GMOT will lead to reduced size, weight, and power (SWaP) of the LPAI sensor head, and, thus, represents an important step towards deployable cold-atom inertial sensors that are robust against vibration, shock, and radiation.

Our multifaceted approach for mobile LPAI operation includes a small form-factor sensor head with a microfabricated grating chip, custom vacuum package, and a compact optomechanical design with fixed optical components (Figs. 1–3); a PIC-compatible laser system architecture (Figs. 4, 5); a high data-rate GMOT and Ramsey interferometry (Figs. 6, 7); and a cold-atom accelerometer based on the GMOT (Fig. 8).

a 3D rendering of the compact LPAI sensor head with fixed optical components and reliable optomechanical design. b Picture of the steady-state GMOT atoms in the sensor head.

a View of the vacuum package looking at the grating chip through the GMOT cooling beam entry window (≈19 mm clear aperture). The external dimensions of a truncated Ti cube are approximately 40.64 × 40.64 × 40.64 mm3. Also visible are Ti tubes which house the rubidium dispensers, getters, and a brazed connection to the Cu exhaust port. b Close-up view of the in-vacuum grating chip and mount prior to being laser-welded to the vacuum package. The grating chip is held in place with 3D-printed swan-neck flexure mounts.

a Horizontal cross-section showing the cooling-beam and atom-detection channels with fixed optical components. The cooling-channel light is delivered to the sensor head via a polarization maintaining (PM) fiber from which a large collimated Gaussian beam (\({{{{{{\rm{D}}}}}}}_{1/{e}^{2}}\approx \,{{{{\rm{28}}}}}\,\,\,{{{{\rm{mm}}}}}\)) is used for cooling. The beam is truncated to ≈ 19 mm-diameter through the fused silica viewport in the compact LPAI sensor head. The light then passes through a polarizer and a λ/4 waveplate before illuminating the grating chip. The GMOT atoms (solid red circle) form ≈ 3.5 mm from the grating surface. The atom-detection channel was designed to measure atomic fluorescence through a multimode-fiber-coupled avalanche photodiode (APD) module. b Vertical cross-section of the sensor head showing the designed beam paths for Doppler-sensitive Raman. Cross-linearly-polarized Raman beams are launched from the same PM fiber and the two components are split by a polarizing beam splitter (PBS). Fixed optics route the Raman beams to the GMOT atoms (solid red circle) with opposite directions. Note: The data of Figs. 7b and 8 were measured with free-space Raman beam optics.

a PIC-based laser system composed of silicon photonics for light modulation, compound semiconductor for optical amplification, and nonlinear photonics for frequency doubling towards a co-packaged laser system and a single hybrid-integrated PIC laser system. (Inset-Left) This image is a four-channel silicon photonic SSBM chip with dual-parallel Mach-Zehnder modulators, simultaneously developed at Sandia70. This PIC chip (8 × 8 mm2) includes 17 silicon photonic phase modulators (4 for each SSBM), variable optical attenuators, thermo-optic phase shifters, optical filters, and photo detectors. (Inset-Right) This image is a fully packaged silicon photonic SSBM, which has been used to generate the Raman beams from a laser in an LPAI demo83. SSBM, single sideband modulator; \({{{\Phi }}}_{{{{{{\rm{MOD}}}}}}}\), phase modulator; SOA, semiconductor optical amplifier; SHG, second harmonic generator. Each channel in the silicon photonics includes a VOA to control the amplitude of the light, and an SOA can function as an optical switch. b PIC-compatible laser system based on discrete components used for the data shown in this paper. f-AOM, fiber-coupled acousto-optic modulator; EDFA, erbium doped fiber amplifier; VOA, variable optical attenuator; SW, optical switch. For Raman 2, we used a f-AOM at 1560 nm and a \({{{\Phi }}}_{{{{{{\rm{MOD}}}}}}}\) at 780 nm, which can be replaced with a SSBM at 1560 nm similar to the PIC-based laser system. The f-AOM is used for the phase lock by continuously monitoring the beat note between the two Raman beams. Fig. 10 shows the beat note measurement and the switching of the Raman beams.

a Optical transitions of 87Rb atoms (D2 transition)79 for LPAI operation. Cooling, Detection, Depump, and Raman 1 beams use \(\left|F=2\right\rangle \) to \(\left|F^{\prime} =1,2,3\right\rangle \) transitions (Left peaks), and Repump and Raman 2 beams use \(\left|F=1\right\rangle \) to \(\left|F^{\prime} =0,1,2\right\rangle \) transitions (Right peaks). The 1560 nm seed laser is frequency-doubled to 780 nm and locked to \(\left|F=2\right\rangle \) to \(\left|F^{\prime} =2,3\right\rangle \) crossover transition with ~1.15 GHz red-detuning from the \(\left|F=2\right\rangle \to \left|F^{\prime} =3\right\rangle \) resonance, which is also used for Raman 1. b Diagram of the timing sequence for LPAI operation highlighting important dynamic changes in the laser channels. The pulse width of Repump/Detection/Raman is not to scale.

a Plot of atom number versus measurement data rate of GMOT operation. b Plot of atom number versus MOT loading time. Error bars are standard deviation.

a The atomic fringe of Ramsey interferometry versus microwave detuning from atomic resonance (ωHF/2π). The interrogation time T is 450 μs, resulting in a fringe spacing of δωRamsey/2π ≃ 2.27 kHz. The measurement data rate is 13.33 Hz. b The atomic fringe of Ramsey interferometry versus Doppler-free Raman detuning from atomic resonance (ωHF/2π). The interrogation time T is 48.08 μs, resulting in a fringe spacing of δωRamsey/2π ≃ 19.74 kHz. The measurement data rate is 10 Hz. Both plots are based on a single shot-to-shot measurement.

a Three-level atomic system for stimulated Raman transitions. \(\left|{g}_{1}\right\rangle =\left|F=1,{m}_{F}=0\right\rangle \), ground state 1; \(\left|{g}_{2}\right\rangle =\left|F=2,{m}_{F}=0\right\rangle \) ground state 2; \(\left|e\right\rangle \), excited state; Δ, single-photon detuning; δ, two-photon detuning which depends on the Doppler shift; ΩRaman, effective Rabi frequency of Raman beams; Ω1, single-photon Rabi frequency of \(\left|{g}_{1}\right\rangle \to \left|e\right\rangle \) transition; Ω2, single-photon Rabi frequency of \(\left|{g}_{2}\right\rangle \to \left|e\right\rangle \) transition. b Space-time trajectory of atomic wavepackets during LPAI. A three-light-pulse sequence, \(\frac{\pi }{2}\to T\to \pi \to T\to \frac{\pi }{2}\), coherently addresses the ground states of the atoms and provides the state-dependent momentum kicks, ℏkeff ≈ 2ℏk, where p0 is the initial atomic momentum; T, the free-evolution time between Raman pulses; keff, the effective wavenumber of stimulated Raman transition; k, the wavenumber (2π/λ) of a single Raman beam. c Scan of the interrogation time showing the LPAI chirped fringe for T = 0.0 ms to 4.5 ms. The fringe chirping results from the Doppler shift of the cold atoms relative to the Raman beams as the atoms accelerate due to gravity. Each data point in the plot is an average of three data points and a slowly-varying offset was removed. The data is fit to a chirped sinusoid92\(\cos \left({k}_{{{{{{\rm{eff}}}}}}}\,{g}_{{{{{{\rm{k}}}}}}}\left({T}^{2}+{\tau }_{{{{{{\rm{\pi }}}}}}}(1+\frac{2}{\pi })T\right)+{\phi }_{0}\right)\), where τπ is the π-pulse duration, gk is gravity, and ϕ0 is an arbitrary phase factor. We measured g = 9.79316(2)ms−2 with the statistical uncertainty of Δg/g = 2.0 × 10−6 without vibration isolation. Plots (d) and (e) provide a detailed view of the chirped fringe of (c) for T = 2.0 ms to 2.1 ms and T = 4.0 ms to 4.1 ms, respectively. The measurement data rate is 10 Hz.

The compact sensor head is designed as a tethered system with a remote electronics and laser system connected via cables and optical fibers (see Fig. 1a). The optomechanical design of the small form-factor sensor head supports a miniaturized Ti vacuum package (including an in-vacuum-mounted microfabricated grating chip) and provides optical access for laser cooling and trapping, Doppler-sensitive Raman transitions, and the fluorescence detection of the atoms. To maximize both manufacturability and efficiency, we chose a GMOT48,49,50,51,52,53,54,55,56 in the production of cold 87Rb atoms for the LPAI because its simple, streamlined design uses a single incoming cooling beam to ensure superior optical access and eliminate unnecessary mechanical degrees of freedom (see Fig. 1b).

For the compact LPAI sensor head, we designed a microfabricated reflective grating chip to form the GMOT48,49,50,51,52,53,54,55,56, which uses a single incoming laser-cooling beam and multiple first-order diffracted beams. The reflective grating chip is based on a triangular geometry with three 1D binary grating sections that generate a tetrahedral GMOT. Although the diffraction efficiency of binary gratings is lower than that of blazed and multilevel gratings, they are simpler to fabricate. First, we designed78 a binary grating for the rubidium D2 transition at 780.24 nm79 to meet a variety of design parameters, including pitch, duty cycle, depth, polarization, and reflective surface material; we simulated first-order and zeroth-order diffraction efficiencies of a binary grating (~50% duty-cycle and 195 nm depth) for s-polarized light (37.88%, 14.29%), p-polarized light (47.75%, 0.92%), and circularly polarized light (40.81%, 7.61%). The first order diffraction angle was 40.56∘ from the incoming beam, which is determined by \({\theta }_{{{{{{\rm{m}}}}}}}={\sin }^{-1}(\frac{{{{{\rm{m}}}}}\lambda }{{{{{\rm{d}}}}}})\) for diffraction order m = 1, pitch d = 1.2 μm, and wavelength λ = 780.24 nm. The fabrication process of the grating chip is shown in Fig. 9b (see Methods). We made the grating pattern in a circular shape (17.5 mm diameter) to match the fused-silica viewport (~19 mm diameter) on the vacuum package. In our GMOT, the estimated capture volume was ≈0.17 cm3. We also diced the grating chip in a hexagonal shape and used the non-grating flat edges for the retainer clips (see Figs. 2b and 9a).

a Schematic of the hexagonal grating chip showing a side-to-side length of 17.5 mm and three grating areas symmetrically arranged in the circular shape. The non-grating flat edges are used for the grating retainer clips. The 1/e2 beam diameter of the cooling beam is 28 mm truncated to ≈19 mm by the fused silica viewport. b Fabrication process of the GMOT grating chip. Parameters for the grating chip used in this paper are tAl = 50nm, \({{{{{{\rm{t}}}}}}}_{{{{{{{\rm{SiO}}}}}}}_{2}}\) = 195 nm, d = 1.2 μm, and ~ 50% duty cycle (details in main text).

The ultra-high vacuum (UHV) package is the centerpiece around which our sensor head was built (Fig. 2a). Briefly, we constructed the vacuum package from Grade-2 titanium (Ti) with five anti-reflection coated fused silica viewports, non-evaporable getters (SAES St172/HI/7.5-7), and alkali-metal dispensers (SAES Rb/NF/3.4/12FT10+10) housed inside Ti tubing laser-welded to the body. Compared to steel, Ti is nonmagnetic, has a lower thermal expansion coefficient, and has a much lower hydrogen outgassing rate. We also brazed a copper exhaust port to the body for evacuation and connected it to an ion pump to maintain the vacuum conditions.

The GMOT grating chip was mounted internally and held with a sintered metal 3D-printed, Ti-alloy (ASTM Ti-6Al-4V) retainer that has four swan-neck flexure mounts, as shown in Fig. 2b. The 3D-printed parts were vacuum baked at 450 ∘C prior to grating chip installation. The flexure mounts provided optical access down to the surface of the grating chip for the Raman beams traveling parallel to the surface and avoided the use of epoxies.

The design of this vacuum package is similar to the passively pumped vacuum package80 that has now demonstrated more than 2 years of magneto-optical trap (MOT) operation without active pumping. Passive pumping eliminates the need for an ion pump, reducing system complexity and SWaP. The passively pumped design in our previous work80 does not include the grating chip and uses C-cut sapphire windows (for reduced birefringence and low-helium permeation), but future designs will include the grating chip.

To achieve deployable cold-atom inertial sensors, we sought to eliminate most of the optomechanical alignment components in the compact sensor head, which was designed to operate in high-vibration and harsh-temperature conditions. In particular, the simplicity of a GMOT approach enables the elimination of unnecessary mechanical degrees of freedom and achieves a compact and reliable optomechanical design. In addition, the time-multiplexed frequency shifting of a single seed laser simplifies the required optical channels for the tethered sensor head.

The optomechanical structure supports the vacuum package and provides the necessary optical routing for the GMOT, atom detection, and Raman beams, while making the sensor head more robust against vibration. As shown in Fig. 3, the main structure surrounding the vacuum package primarily consists of a combination of FR4 fiberglass composite (green) and 30% glass-filled PEEK (brown). These non-conductive materials near the coils reduce the effects of eddy currents. We mechanically held the optical components while curing the epoxy (3M Scotch-Weld EC 2216, certified for use in aircraft and aerospace applications).

In Fig. 3a, the horizontal cross-section view of the compact LPAI sensor head shows the fixed optical components for cooling-beam and atom-detection channels for the GMOT. When the grating chip is in operation (see Figs. 3b and 2b), a single incoming laser-cooling beam and three first-order diffracted beams form a tetrahedral GMOT with a quadrupole magnetic field created by anti-Helmholtz coils. All four cooling beams and the magnetic field zero point have to be aligned to the same point in 3D space. We achieved the final alignment of the cooling beam to the grating using a 6-axis piezo stage that actively aligns the fiber-port-concave-lens assembly while monitoring the atomic cloud fluorescence via a CMOS camera (Imaging Source DMM 37UX265-ML) attached to the sensor head. After that, all the optics were bonded in place. For the steady-state GMOT atoms, the diameter of the atomic clouds was ~ 0.8 mm perpendicular to the grating and ~1.7 mm parallel to the grating; the distance between the atomic clouds and the grating surface was ~3.5 mm. The repump/detection beam was coupled through the same assembly (as the cooling beam) with the same polarization.

Figure 3b shows our original design for counter-propagating Raman beams, and the vertical cross-section view of the compact LPAI sensor head, which includes the fixed optical components for cross-linearly-polarized Raman beams, Raman power monitor ports, and cooling beam channels. In this design, the Raman light is brought to the sensor head with a polarization maintaining (PM) optical fiber where two Raman beams propagate along the fast and slow axes of the fiber. The Raman fiber launch assembly collimates the light, and a 45 ∘-angled mirror brings the light into the plane of Fig. 3b. After this, the two Raman beams are split by the first polarizing beam splitter (PBS) and become counter-propagating Doppler-sensitive Raman beams. The downward and upward Raman beams are then applied to the atoms released from the GMOT, driving the state-dependent momentum kicks on the atoms for LPAI operation. The Raman power monitor ports couple light into multimode fibers, so that the pulse amplitude of each Raman beam can be measured. We initially performed the alignment without the GMOT atoms using high-precision 6-axis piezo stages such that the Raman beams intersected at their designed position. However, in practice, we found a mismatch between the optimized GMOT position and the designed Raman beam position. We note that the data shown below (Figs. 7b and 8) was taken by substituting the fixed Raman optics with conventional free-space optics in order to optimize LPAI performance. This mismatch can be suppressed in subsequent versions of the sensor head and further reduced with active alignment or flat-top Raman beams81 to improve spatial-overlap homogeneity.

Our detection collects the atomic fluorescence of the GMOT atoms from a spherical region ~3 mm in diameter, where the atomic cloud exists during the LPAI operation. It consists of two focusing elements and a multimode-fiber-coupled avalanche photodiode (APD), as shown in Fig. 3a. The optics were centered in their housing using shims, secured into the housing with a threaded retaining ring to maximize the atomic fluorescence, then bonded into place.

The development of a compact high-performance laser system is essential to reduce design complexity and improve reliability in a dynamic environment. The long-term goal is to achieve extreme miniaturization of the laser system by integrating nearly all of the required optical components onto a single PIC. Over the last decade, silicon-based PICs operating in the telecom C-band have matured substantially, providing the components required for optical telecommunication. In addition, the heterogeneous integration of PIC components is ongoing; for example, silicon photonics can be integrated with compound semiconductors to form lasers and optical amplifiers73,74, nonlinear material (e.g., thin-film lithium niobate) to create electro-optic modulators71,72, and Brillouin-active membrane to form Brillouin lasers and amplifiers75. In addition, nonlinear photonics (second harmonic generation, SHG) has been demonstrated on a silicon-photonics-compatible platform with lithium niobate resonators76 and aluminum nitride waveguides77.

These ongoing efforts would bring modulators, optical amplifiers, frequency doublers, and even laser sources onto the PIC to achieve a fully integrated laser solution for an LPAI sensor. Using a PIC, the optical frequency can be manipulated at 1560 nm and then frequency-doubled to 780 nm (the Rb D2 line). Because chip-based technologies are highly scalable, moving from a single-axis accelerometer to a three-axis accelerometer or a complete LPAI-based inertial measurement unit can be readily envisioned using PIC technology. Here, we outlined a potential PIC-based concept (for a PIC laser architecture) and demonstrated a “PIC-compatible” laser system, showing that the architecture is functional for an LPAI using discrete COTS components.

As shown in Fig. 4a, our PIC-based laser system (based on a 1560-to-780 nm approach), aims to realize a mass-producible, chip-scale laser system with integrated photonics for laser cooling and trapping and atom interferometry. This laser system has three major functions: light modulation (silicon photonics), optical amplification (compound semiconductor), and frequency doubling (nonlinear photonics). A silicon PIC chip achieves light modulation using multichannel SSBMs70, where a 1 × N silicon nitride splitter divides an off-chip seed laser (1560 nm) into multiple channels. Within each channel, a SSBM is used to frequency offset the light to the required frequency for the particular function of the channel. The SSBM allows the light frequency to be rapidly switched (time-multiplexed frequency shifting), allowing a single channel to perform multiple functions, such as repump light for the MOT and detection light for state read out (see Figs. 4 and 5). A 1560-nm wavelength silicon PIC chip70 includes frequency/phase modulators82, thermo-optic phase shifters, variable optical attenuators (VOAs), optical filters, and photo-detectors (to monitor the performance of the other components). After passing through the SSBM, the light goes into a 1560 nm high-power semiconductor optical amplifier (SOA) that produces up to 500 mW, and then passes through a high-efficiency frequency doubler to convert the light to 780 nm.

The architecture shown in Fig. 4a was chosen because the essential components can be realized (or are close to being realized) with existing PIC technologies. By developing these building blocks, our team has successfully implemented a four-channel SSBM on a silicon PIC (Fig. 4a inset) and performed an initial demonstration with the silicon PIC to generate the Raman beams in an LPAI83. Our team is currently developing a high-power multi-stage SOA with compound semiconductor and a nonlinear photonics frequency doubler. This SOA could also operate as a high-speed (sub-nanosecond) optical switch84 with a high extinction ratio. Using a lithium niobate platform with shallow etched waveguides85 for the frequency doubler, our team demonstrated 939% W−1 SHG conversion efficiency. While Fig. 4a shows separate PICs for the silicon photonics, compound semiconductor, and nonlinear photonics, we envision a future PIC where all required optical components are hybrid-integrated into a single PIC.

The PIC-compatible laser system is shown in Fig. 4b, where essential functions of the PIC architecture are replaced with fiber-connected COTS components. A single 1560 nm fiber seed laser with ≤3 kHz linewidth (NP Photonics FLM-150-3-1560.49-1-S-A) splits into five channels: (1) Lock, (2) Cooling, (3) Repump/Detection, (4) Raman 1, and (5) Raman 2. Channels 1, 2, 3 share a similar architecture, frequency-shifting the light from the seed laser using the SSBM63,64 (IQ modulator, Eospace IQ-0D6S-25-PFA-PFA-LV). The Lock channel has an additional phase modulator (\({{{\Phi }}}_{{{{{{\rm{MOD}}}}}}}\), Eospace PM-0S5-10-PFA-PFA-UL) placed after the SSBM to stabilize the frequency of the seed laser to a 87Rb reference (\(\left|F=2\right\rangle \to \left|F^{\prime} =2,3\right\rangle \) crossover resonance in 87Rb) with frequency modulation saturation spectroscopy. The 1560 nm light is then amplified by an erbium-doped fiber amplifier (EDFA, IPG Photonics EAR-2K-C-LP-SF) and passes through a high-power electro-optic VOA (Agiltron NHOA-325115333) and a high-power electro-optic optical switch (SW, Agiltron NHSW-115115333) before frequency doubling to 780 nm with the fiber-SHG modules (SHG, AdvR RSH-T0780-P15P78AL0).

The Cooling channel provides the cooling light on the \(\left|F=2\right\rangle \to \left|F^{\prime} =3\right\rangle \) transition with an intensity of about 1.1 mW cm−2 and a detuning of − 1 Γ for steady-state GMOT operation (see Fig. 5a), where Γ/2π = 6.065 MHz for 87Rb D2 transition. After the GMOT is loaded, sub-Doppler cooling is accomplished with a frequency ramp from −1 Γ to −13.5 Γ and a VOA-controlled intensity ramp (Fig. 5b). We determined a 15 μK temperature of sub-Doppler cooled GMOT atoms by evaluating the width of the Doppler-sensitive Raman resonance. After sub-Doppler cooling, the repump light is extinguished and the Cooling channel jumps to the \(\left|F=2\right\rangle \to \left|F^{\prime} =2\right\rangle \) transition to depump the atoms into the \(\left|F=1\right\rangle \) hyperfine ground state (Fig. 5b).

For fluorescence detection, the Repump/Detection channel is first resonant with the \(\left|F=2\right\rangle \to \left|F^{\prime} =3\right\rangle \) transition to detect atoms in the \(\left|F=2\right\rangle \) state (see Fig. 5a). It then jumps to \(\left|F=1\right\rangle \to \left|F^{\prime} =2\right\rangle \) to repump all atoms into the \(\left|F=2\right\rangle \) state before jumping back to the \(\left|F=2\right\rangle \to \left|F^{\prime} =3\right\rangle \) transition to detect all of the atoms (Fig. 5b). For our experiment, we coupled the Repump/Detection channel to the same fiber as the Cooling channel with the same polarization.

The cross-linearly-polarized Raman beams control the internal states of the atoms, which are composed of two light frequency components (Raman 1 and Raman 2) using stimulated Raman transitions (Fig. 8a). In particular, Doppler-sensitive Raman beams provide the state-dependent momentum kicks required to construct atom interferometry in the space-time trajectory and measure inertial forces on the atoms. We derived both Raman frequencies from the same 1560 nm seed laser, as shown in Fig. 4b. Raman 1 is the frequency-doubled seed laser (780 nm) that is ~1.15 GHz red-detuned from the \(\left|F=2\right\rangle \to \left|F^{\prime} =3\right\rangle \) resonance. Raman 2 is frequency-offset via a fiber-coupled 1560 nm acousto-optic modulator (AOM) operating at −150 MHz. The frequency-offset light is then amplified by a 1560 nm SOA and frequency-doubled to 780 nm. After that, Raman 2 is phase-modulated by a 780 nm phase modulator and then amplified by a 780 nm SOA. Fig. 10 shows how the Raman beams are combined, with 10% of the light used for phase locking (see Methods). In the results shown below, Raman spectroscopy was applied to Ramsey interferometry with co-propagating Doppler-free Raman beams (Fig. 7b) and atom interferometry with counter-propagating Doppler-sensitive Raman beams (Fig. 8c).

Approximately 10% of the combined power is diverted for phase locking while the remaining power is directed towards an acousto-optic modulator for pulsing. The combined Raman beams are coupled into the same polarization maintaining fiber with the polarizations aligned to the slow and fast axes of the fiber. PBS polarizing beam splitter, R90:T10, non-polarizing cube beam splitter; Pol. polarizer, AOM acousto-optic modulator.

We developed the compact sensor head (Figs. 1–3) and the PIC-compatible laser system (Figs. 4, 5) as a step towards deployable cold-atom inertial sensors. Using these components, we demonstrated a high data-rate sub-Doppler-cooled GMOT with a single laser-cooling beam (Fig. 6), validated atomic coherence with Ramsey interferometry (Fig. 7), and performed proof-of-concept LPAI operation and a measurement of gravity (Fig. 8).

A short time-of-flight approach enables high data-rate operation and enhances the bandwidth of LPAIs41,42 by mitigating the detrimental effects of sensor head movement during operation, which can ruggedize LPAIs for use in a dynamic environment with modest sensitivity. Efficient atom recapture is critical to maintaining a reasonably high atom number during high data-rate operation. In our system, high data-rate LPAI operation follows this sequence: (1) capture and cool atoms from background vapor with a GMOT, (2) perform sub-Doppler cooling, (3) prepare the atoms in the \(\left|F=1\right\rangle \) state, (4) release to free space, (5) perform physics experiments, (6) detect the atomic populations, and (7) recapture atoms for the next measurement cycle.

Here, we demonstrated proof-of-concept high data-rate GMOT operation by measuring the sub-Doppler cooled atom number vs. data rate (see Fig. 6a, b). For this measurement, we determined the atom number by the absorption of a probe beam resonant with the \(\left|F=2\right\rangle \to \left|F^{\prime} =3\right\rangle \) transition. Within a measurement cycle, the MOT was loaded for a variable amount of time before the quadrupole magnetic field was turned off. Sub-Doppler cooling and depumping to \(\left|F=1\right\rangle \) occurred over the next 3 ms and was followed by a 13 ms window for physics experiments and state detection. At the end of the window, the cooling light and quadrupole field were turned back on to recapture atoms and restart MOT loading. The data rate is the inverse of the total cycle time. The number of sub-Doppler-cooled GMOT atoms decreased as the data rate increased, as shown in Fig. 6a; the same data is replotted in Fig. 6b, as the MOT loading time increased. At present, the data-rate measurement of GMOT operation is limited by the data rate of the control system and the low recapture efficiency, likely due to the low GMOT cooling intensity86.

We examined atomic coherence to show that the system is not limited by decoherence due to background collisions/pressure and spatial-overlap inhomogeneity between cold atoms and Raman beams. We observed Rabi oscillations and Ramsey fringes of the GMOT atoms using both a microwave field and co-propagating Doppler-free Raman beams that address the "clock” transition in the hyperfine ground-state manifold, i.e., \(\left|F=1,{m}_{F}=0\right\rangle \) to \(\left|F=2,{m}_{F}=0\right\rangle \).

In Rabi measurement with a microwave field, the Rabi frequency was 10 kHz (T2π = 100 μs), and the Rabi coherence time was τ1/e ≃ 676 μs. In Rabi measurement with Doppler-free Raman beams, the Rabi frequency was 130 kHz (T2π = 7.68 μs) and the Rabi coherence time was τ1/e ≃ 8.3 μs. The measured pulse times of the Rabi measurements were used for the Ramsey measurements.

For the Ramsey interferometry study (\(\frac{\pi }{2}\to T\to \frac{\pi }{2}\)), the frequency detuning of the two \(\frac{\pi }{2}\)-pulses was scanned for a fixed time T to measure atomic interference fringes based on the two hyperfine ground states, as shown in Fig. 7. In Ramsey measurement with a microwave field, the fringe spacing was 2.27 kHz from the data fitting, which was consistent with 1/T for T = 450 μs (see Fig. 7a). In Ramsey measurement with Doppler-free Raman beams, the fringe spacing was 19.74 kHz from the data fitting, which also corresponds to 1/T for T = 48.08 μs (see Fig. 7b).

The improvement of spatial-overlap homogeneity between the GMOT atoms and the Raman beams becomes important to achieve the best performance in Ramsey interferometry and atom interferometry87. In the experiment, the current ratio of the diameter of the atomic clouds (parallel to the grating, ~1.7 mm) to the beam diameter of the Raman beams (\({{{{{\rm{{D}}}}}_{1/{e}^{2}}}}\simeq \,{{{{\rm{5.4}}}}}\,\,\,{{{{\rm{mm}}}}}\,\)) was comparable to one-third. The spatial-overlap homogeneity can be further enhanced with flat-top Raman beams81 or large Raman beams81.

We demonstrated proof-of-concept LPAI operation and gravity measurement using a GMOT, integrating all of our microfabricated grating chips, custom Ti vacuum packages, a compact-form-factor LPAI sensor head, and PIC-compatible laser systems with time-multiplexed frequency shifting.

In a gravimeter configuration, the LPAI accelerometer operates using stimulated Raman transitions (Fig. 8a), which coherently addresses the two hyperfine ground states of atoms, i.e., \(\left|F=1,{m}_{F}=0\right\rangle \) and \(\left|F=2,{m}_{F}=0\right\rangle \), and drives photon recoils on the atoms along the direction of gravity using counter-propagating Raman beams. The three-light-pulse sequence of the LPAI coherently splits, redirects, and recombines atomic wavepackets for atomic interference in a space-time trajectory (Fig. 8b). The atomic interference fringe is sensitive to inertial forces that the atoms experience during the LPAI pulse sequence, and the phase shift provides gravitational acceleration information.

As discussed in Fig. 3, we optimized spatial overlap between the GMOT atoms and the Raman beams using free-space optomechanical components around the sensor head for Raman beams instead of the fully fixed optical components shown in Fig. 3b. The sensor head assembly was located on a countertop without any vibration isolation. The LPAI accelerometer measures the gravitational acceleration by the phase shift of the atomic interference fringe, i.e., Δϕacc = keff ⋅ aT2, when the sensing axis of Doppler-sensitive Raman beams is aligned to the gravity direction (a = g). The Raman quantization axis was defined along the Z-axis with a magnetic field of 1.34 G, and the sensor head was located inside a single-layer magnetic shield. Since the velocity of the atoms increased linearly due to g, the LPAI fringe became chirped as the interrogation time T was increased. Based on the fit of a chirped sinusoid41, we measured g = 9.79316(2) ms−2 with LPAI operation up to T = 4.5 ms, as shown in Fig. 8c–e. The statistical uncertainty was Δg/g = 2.0 × 10−6 from the fitting the data for T = 0.0–4.5 ms.

We demonstrated a compact-form-factor high-data-rate atom interferometer with a PIC-compatible laser system architecture. One of our primary goals was to enable operation of the LPAI in high-dynamic environments (environments with large jerk), so our LPAI subsystems were designed with robustness in mind. First, the compact cold-atom sensor head used fixed optical components, a custom vacuum package, and a microfabricated grating chip for the GMOT—all designed to enable ruggedization and miniaturization of the system. Using rigid materials for the miniaturized fixed-optics assembly is essential for decreasing the relative movement of components under changes in acceleration. Random vibration analysis of the compact sensor head showed good stability for the GMOT, but improvements are necessary for the Raman beam path for large changes in acceleration. Second, the high data-rate operation of the LPAI using the sub-Doppler cooled atoms from the GMOT can enable operation through large dynamics in a number of ways. For example, decreasing the drop time reduces the sensitivity, but also keeps the size of the system small, minimizes the relative movement between cold atoms and the Raman beams (reducing the effects of cross-axis acceleration), and allows recapture of the atoms. While not discussed in this paper, a feedforward scheme can also enable operation over a large dynamic range88; in this scheme, conventional sensors measure inertial forces at a rate much larger than 1/T, and these signals are processed to “feedforward” to the Raman lasers (primarily the phase, but also the amplitude and frequency) to lock the LPAI to the side of an LPAI fringe. The feedforward scheme addresses mainly on-axis acceleration but can also mitigate cross-axis acceleration, cross-axis rotation, and vibration-induced noise on an LPAI fringe. Third, a PIC laser architecture is the ultimate in miniaturization for the laser system, and typically, the smaller the system size, the more dimensionally stable it is, allowing more tolerance to vibration. As part of our overall LPAI effort, we simultaneously developed the PIC-based laser system components (Fig. 5a inset), and validated our conceptual approach by using the PIC-compatible laser system for the LPAI demonstration.

Our results show the potential for compact, multi-axis, and deployable cold-atom inertial sensors with microfabricated grating chips, although continued effort will be required to realize a fully integrated LPAI system for dynamic environments. Near-term improvements to our sensor head include a redesign of the Raman opto-mechanics to optimize overlap with the atoms and enhance mechanical stability. We also plan to improve the data rate of our GMOT LPAI by using a flat-top cooling beam with higher power to increase the initial atom number. Longer-term, the PIC components must see continued development, and hybrid integration strategies must be matured to realize a complete PIC-based laser system. We anticipate that a PIC laser system will significantly decrease cost and reduce manufacturing and testing time in realizing a complete matter-wave inertial measurement unit with three-axis atomic accelerometers and three-axis atomic gyroscopes, which will have tens of optical channels. The technologies developed in these ongoing efforts can also be applied beyond LPAI gravimeters, gravity gradiometers, accelerometers, and gyroscopes to other real-world atomic sensor applications, such as clocks, magnetometers, and electric field sensors.

The fabrication process is shown in Fig. 9b. A 195 nm layer of SiO2 was grown on a silicon wafer followed by spin-coating and soft-baking the e-beam resist (ER). The 1D binary grating was then patterned in the ER via e-beam lithography. The pattern was etched into the SiO2 using a selective reactive ion etching (RIE) process, stopping on the silicon. The ER was then removed with solvents and all remaining organic residue was removed in an O2 plasma. A 50 nm reflective coating of aluminum (Al) was deposited conformally over the etched SiO2 grating, using an angled and rotating platen in an e-beam evaporator. We chose Al over Au because the grating is necessarily inside the vacuum, where Rb can interact with the Au and substantially reduce its reflectivity89, and Al gratings have been tested with Rb atoms inside the vacuum90,91. The e-beam bias and the added sidewall thickness were carefully controlled to minimize errors in the target pitch, duty cycle, and depth of the grating.

For the Raman channels, time-multiplexed frequency shifting can also be implemented, but was not pursued here in order to simplify phase stabilization. Both Raman beams were combined with orthogonal polarization using free-space optics, as shown in Fig. 10. A sample of the combined beams (~10%) was used for continuous Raman phase stabilization through the fiber-coupled 1560 nm AOM (or SSBM) and a voltage-controlled oscillator, while the majority of the power was sent to a free-space AOM for optical switching. The combined Raman light was then coupled to a single PM fiber along its two birefringent axes for delivery to the LPAI sensor head, reducing noise from varying paths.

All relevant data are available from the authors upon reasonable request.

Simulation code is available from the authors upon reasonable request.

Heavner, T. P. et al. First accuracy evaluation of NIST-F2. Metrologia 51, 174–182 (2014).

Article ADS CAS Google Scholar

Wynands, R. & Weyers, S. Atomic fountain clocks. Metrologia 42, S64–S79 (2005).

Article ADS CAS Google Scholar

Nicholson, T. L. et al. Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty. Nat. Comm.6, 1 (2015).

Google Scholar

Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E. & Schmidt, P. O. Optical atomic clocks. Rev. Mod. Phys. 87, 637–701 (2015).

Article ADS CAS Google Scholar

Dang, H. B., Maloof, A. C. & Romalis, M. V. Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer. App. Phys. Lett. 97, 151110 (2010).

Article ADS CAS Google Scholar

Holloway, C. L. et al. Broadband rydberg atom-based electric-field probe for SI-Traceable, self-calibrated measurements. IEEE Trans. Antennas Propagation. 62, 6169–6182 (2014).

Article ADS MathSciNet MATH Google Scholar

Johnson, C., Schwindt, P. D. D. & Weisend, M. Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer. App. Phys. Lett. 97, 243703 (2010).

Article ADS CAS Google Scholar

Grujic, Z., Koss, P. A., Bison, G. & Weis, A. A sensitive and accurate atomic magnetometer based on free spin precession. Eur. Phys. J. D 69, 135 (2015).

Maze, J. R. M. et al. Nanoscale magnetic sensing with an individual electronic spin in diamond. Nature 455, 644–647 (2008).

Article ADS CAS PubMed Google Scholar

Balasubramanian, G. et al. Nanoscale imaging magnetometry with diamond spins under ambient conditions. Nature 455, 648–651 (2008).

Article ADS CAS PubMed Google Scholar

Kasevich, M. & Chu, S. Atomic interferometry using stimulated Raman transitions. Phys. Rev. Lett. 67, 181–184 (1991).

Article ADS CAS PubMed Google Scholar

Gustavson, T. L., Bouyer, P. & Kasevich, M. A. Precision rotation measurements with an atom interferometer gyroscope. Phys. Rev. Lett. 78, 2046–2049 (1997).

Article ADS CAS Google Scholar

Peters, A., Chung, K. Y. & Chu, S. Measurement of gravitational acceleration by dropping atoms. Nature 400, 849–852 (1999).

Article ADS CAS Google Scholar

McGuirk, J. M., Foster, G. T., Fixler, J. B., Snadden, M. J. & Kasevich, M. A. Sensitive absolute-gravity gradiometry using atom interferometry. Phys. Rev. A 65, 033608 (2002).

Article ADS CAS Google Scholar

Cronin, A. D., Schmiedmayer, J. & Pritchard, D. E. Optics and interferometry with atoms and molecules. Rev. Mod. Phys. 81, 1051–1129 (2009).

Article ADS CAS Google Scholar

Kovachy, T. et al. Quantum superposition at the half-metre scale. Nature 528, 530–533 (2015).

Article ADS CAS PubMed Google Scholar

Parker, R. H., Yu, C., Zhong, W., Estey, B. & Müller, H. Measurement of the fine-structure constant as a test of the Standard Model. Science 360, 191–195 (2018).

Article ADS MathSciNet CAS PubMed MATH Google Scholar

Geiger, R., Landragin, A., Merlet, S. & Pereira Dos Santos, F. High-accuracy inertial measurements with cold-atom sensors. AVS Quantum Science 2, 024702 (2020).

Article ADS Google Scholar

Tino, G. M. Testing gravity with cold atom interferometry: results and prospects. Quantum Sci. Technol. 6, 024014 (2021).

Article ADS Google Scholar

Asenbaum, P., Overstreet, C., Kim, M., Curti, J. & Kasevich, M. A. Atom-interferometric test of the equivalence principle at the 10−12 level. Phys. Rev. Lett. 125, 191101 (2020).

Article ADS CAS PubMed Google Scholar

Bongs, K. et al. Taking atom interferometric quantum sensors from the laboratory to real-world applications. Nat. Rev. Phys. 1, 731–739 (2019).

Article Google Scholar

Canuel, B. et al. Six-axis inertial sensor using cold-atom interferometry. Phys. Rev. Lett. 97, 010402 (2006).

Article ADS CAS PubMed Google Scholar

Hardman, K. S. et al. Simultaneous precision gravimetry and magnetic gradiometry with a bose-einstein condensate: A high precision, quantum sensor. Phys. Rev. Lett. 117, 138501 (2016).

Article ADS CAS PubMed Google Scholar

Wu, X. et al. Multiaxis atom interferometry with a single-diode laser and a pyramidal magneto-optical trap. Optica 4, 1545–1551 (2017).

Article ADS CAS Google Scholar

Chen, Y.-J. et al. Single-source multiaxis cold-atom interferometer in a centimeter-scale cell. Phys. Rev. Applied 12, 014019 (2019).

Article ADS CAS Google Scholar

Rosi, G., Sorrentino, F., Cacciapuoti, L., Prevedelli, M. & Tino, G. M. Precision measurement of the Newtonian gravitational constant using cold atoms. Nature 510, 518–521 (2014).

Article ADS CAS PubMed Google Scholar

Canuel, B. et al. Exploring gravity with the MIGA large scale atom interferometer. Sci. Rep. 8, 14064 (2018).

Zhan, M.-S. et al. ZAIGA: Zhaoshan long-baseline atom interferometer gravitation antenna. Int. J. Mod. Phys. D 29, 1940005 (2020).

Article ADS Google Scholar

Overstreet, C., Asenbaum, P., Curti, J., Kim, M. & Kasevich, M. A. Observation of a gravitational aharonov-bohm effect. Science 375, 226–229 (2022).

Article ADS MathSciNet CAS PubMed Google Scholar

Wu, X. et al. Gravity surveys using a mobile atom interferometer. Sci. Adv. 5, eaax0800 (2019).

Stray, B. et al. Quantum sensing for gravity cartography. Nature 602, 590–594 (2022).

Article ADS CAS PubMed PubMed Central Google Scholar

Hinton, A. et al. A portable magneto-optical trap with prospects for atom interferometry in civil engineering. Philos. Trans. A Math. Phys. Eng. Sci. 375, 20160238 (2017).

ADS PubMed PubMed Central Google Scholar

Narducci, F. A., Black, A. T. & Burke, J. H. Advances toward fieldable atom interferometers. Adv. Phys. X 7, 1946426 (2022).

Google Scholar

Ménoret, V. et al. Gravity measurements below 10−9g with a transportable absolute quantum gravimeter. Sci. Rep. 8, 12300 (2018).

Bidel, Y. et al. Absolute marine gravimetry with matter-wave interferometry. Nat. Commun. 9, 627 (2018).

Article ADS CAS PubMed PubMed Central Google Scholar

Geiger, R. et al. Detecting inertial effects with airborne matter-wave interferometry. Nat. Commun. 2, 474 (2011).

Barrett, B. et al. Dual matter-wave inertial sensors in weightlessness. Nat. Commun. 7, 13786 (2016).

Bidel, Y. et al. Absolute airborne gravimetry with a cold atom sensor. J. Geodesy 94, 20 (2020).

Article ADS Google Scholar

Becker, D. et al. Space-borne Bose-Einstein condensation for precision interferometry. Nature 562, 391–395 (2018).

Article ADS CAS PubMed Google Scholar

Aveline, D. C. et al. Observation of Bose-Einstein condensates in an Earth-orbiting research lab. Nature 582, 193–197 (2020).

Article ADS CAS PubMed Google Scholar

McGuinness, H. J., Rakholia, A. V. & Biedermann, G. W. High data-rate atom interferometer for measuring acceleration. Appl. Phys. Lett. 100, 011106 (2012).

Article ADS CAS Google Scholar

Rakholia, A. V., McGuinness, H. J. & Biedermann, G. W. Dual-axis high-data-rate atom interferometer via cold ensemble exchange. Phys. Rev. Applied 2, 054012 (2014).

Article ADS CAS Google Scholar

Adams, B. et al. The development of a High data rate atom interferometric gravimeter (HIDRAG) for gravity map matching navigation. In 2021 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL), 1–4, (2021).

Nagy, J. A. & Coble, G. L., Jr. Flight vibration data of the aerobee 150A sounding rocket. Tech. Rep., NASA (1964).

Schoenster, J. A. Measurements and analysis of solid-propellant-rocket vibrations obtained during a captive flight. Tech. Rep., NASA (1971).

Office, S. R. P. NASA sounding rockets user handbook. Tech. Rep., NASA (2015).

Travagnin, M. Cold atom interferometry for inertial navigation sensors. technology assessment: space and defence applications. Tech. Rep., Joint Research Centre (2020). https://doi.org/10.2760/237221.

Vangeleyn, M., Griffin, P. F., Riis, E. & Arnold, A. S. Laser cooling with a single laser beam and a planar diffractor. Opt. Lett. 35, 3453–3455 (2010).

Article ADS CAS PubMed Google Scholar

Nshii, C. C. et al. A surface-patterned chip as a strong source of ultracold atoms for quantum technologies. Nat. Nanotechnol. 8, 321–324 (2013).

Article ADS CAS PubMed Google Scholar

Lee, J., Grover, J. A., Orozco, L. A. & Rolston, S. L. Sub-Doppler cooling of neutral atoms in a grating magneto-optical trap. J. Opt. Soc. Am. B 30, 2869–2874 (2013).

Article ADS CAS Google Scholar

Imhof, E. et al. Two-dimensional grating magneto-optical trap. Phys. Rev. A 96, 033636 (2017).

Article ADS Google Scholar

McGilligan, J. P. et al. Grating chips for quantum technologies. Sci. Rep. 7, 384 (2017).

Article ADS PubMed PubMed Central CAS Google Scholar

Barker, D. S. et al. Single-beam zeeman slower and magneto-optical trap using a nanofabricated grating. Phys. Rev. Appl. 11, 064023 (2019).

Article ADS CAS Google Scholar

Sitaram, A. et al. Confinement of an alkaline-earth element in a grating magneto-optical trap. Rev. Sci. Instrum. 91, 103202 (2020).

Article ADS CAS PubMed Google Scholar

McGehee, W. R. et al. Magneto-optical trapping using planar optics. New J. Phys. 23, 013021 (2021).

Article ADS CAS Google Scholar

Seo, S. et al. Maximized atom number for a grating magneto-optical trap via machine-learning assisted parameter optimization. Opt. Express 29, 35623–35639 (2021).

Article ADS CAS PubMed Google Scholar

Perrin, I. et al. Zero-velocity atom interferometry using a retroreflected frequency-chirped laser. Phys. Rev. A 100, 053618 (2019).

Article ADS CAS Google Scholar

Lévèque, T., Antoni-Micollier, L., Faure, B. & Berthon, J. A laser setup for rubidium cooling dedicated to space applications. Appl. Phys. B 116, 997–1004 (2014).

Article ADS CAS Google Scholar

Schkolnik, V. et al. A compact and robust diode laser system for atom interferometry on a sounding rocket. Appl. Phys. B 122, 217 (2016).

Caldani, R. et al. A prototype industrial laser system for cold atom inertial sensing in space. Eur. Phys. J. D 73, 248 (2019).

Sabulsky, D. O. et al. A fibered laser system for the MIGA large scale atom interferometer. Sci. Rep. 10, 3268 (2020).

Frye, K. et al. The bose-einstein condensate and cold atom laboratory. EPJ Quantum Technol. 8, 1 (2021).

Zhu, L. et al. Application of optical single-sideband laser in Raman atom interferometry. Opt. Express 26, 6542–6553 (2018).

Article ADS CAS PubMed Google Scholar

Rammeloo, C., Zhu, L., Lien, Y.-H., Bongs, K. & Holynski, M. Performance of an optical single-sideband laser system for atom interferometry. J. Opt. Soc. Am. B 37, 1485–1493 (2020).

Article ADS CAS Google Scholar

Chiow, S.-W. & Yu, N. Compact atom interferometer using single laser. Appl. Phys. B 124, 96 (2018).

Article ADS CAS Google Scholar

Fang, J. et al. Realization of a compact one-seed laser system for atom interferometer-based gravimeters. Opt. Express 26, 1586–1596 (2018).

Article ADS CAS PubMed Google Scholar

Macrae, C. D., Bongs, K. & Holynski, M. Optical frequency generation using fiber Bragg grating filters for applications in portable quantum sensing. Opt. Lett. 46, 1257–1260 (2021).

Article ADS PubMed Google Scholar

Additively manufactured ultra-high vacuum chamber for portable quantum technologies. Additive Manufacturing 40, 101898, (2021).

Madkhaly, S. et al. Performance-optimized components for quantum technologies via additive manufacturing. PRX Quantum 2, 030326 (2021).

Article ADS Google Scholar

Kodigala, A. et al. Silicon Photonic Single-Sideband Generation with Dual-Parallel Mach-Zehnder Modulators. In Conference on Lasers and Electro-Optics, STh4N.6, https://doi.org/10.1364/CLEO_SI.2019.STh4N.6 (Optical Society of America, 2019).

Weigel, P. O. et al. Bonded thin film lithium niobate modulator on a silicon photonics platform exceeding 100 GHz 3-dB electrical modulation bandwidth. Opt. Express 26, 23728–23739 (2018).

Article ADS CAS PubMed Google Scholar

Boynton, N. et al. A heterogeneously integrated silicon photonic/lithium niobate travelling wave electro-optic modulator. Opt. Express 28, 1868–1884 (2020).

Article ADS CAS PubMed Google Scholar

Heck, M. J. R. et al. Hybrid silicon photonics for optical interconnects. IEEE J. Select. Top. Quantum Electron. 17, 333–346 (2011).

Article ADS CAS Google Scholar

Davis, J. A. et al. III/V silicon hybrid laser based on a resonant Bragg structure. Appl. Opt. 59, 4158–4164 (2020).

Article ADS CAS PubMed Google Scholar

Otterstrom, N. T. et al. Resonantly enhanced nonreciprocal silicon Brillouin amplifier. Optica 6, 1117–1123 (2019).

Article ADS CAS Google Scholar

Moore, J. et al. Efficient second harmonic generation in lithium niobate on insulator. In Conference on Lasers and Electro-Optics, STh3P.1, https://doi.org/10.1364/CLEO_SI.2016.STh3P.1 (Optical Society of America, 2016).

Siddiqui, A. M. et al. Optimization of Si-Photonics Compatible AlN waveguides for Integrated Nonlinear Optics Applications. In Conference on Lasers and Electro-Optics, JTu2A.96, https://doi.org/10.1364/CLEO_AT.2019.JTu2A.96 (Optical Society of America, 2019).

Johnson, K. C. Grating Diffraction Calculator GD-Calc®, https://doi.org/10.24433/CO.7479617.v3.

Steck, D. A. Rubidium 87 D Line Data. http://steck.us/alkalidata.

Little, B. J. et al. A passively pumped vacuum package sustaining cold atoms for more than 200 days. AVS Quantum Sci. 3, 035001 (2021).

Article ADS CAS Google Scholar

Mielec, N. et al. Atom interferometry with top-hat laser beams. Appl. Phys. Lett. 113, 161108 (2018).

Article ADS CAS Google Scholar

DeRose, C. T., Trotter, D. C., Zortman, W. A. & Watts, M. R. High speed travelling wave carrier depletion silicon mach-zehnder modulator. In Opt. Interconnects Conf., 135–136, https://doi.org/10.1109/OIC.2012.6224486 (SPIE, 2012).

Kodigala, A. et al. Silicon Photonic single-sideband generation with dual-parallel mach-zehnder modulators for atom interferometry applications. arXiv:2204.12537. https://doi.org/10.48550/arXiv.2204.12537 (2022).

Ju, H. et al. Soa-based all-optical switch with subpicosecond full recovery. Opt. Express 13, 942–947 (2005).

Article ADS CAS PubMed Google Scholar

Zhao, J. et al. Shallow-etched thin-film lithium niobate waveguides for highly-efficient second-harmonic generation. Optics Express 28, 19669–19682 (2020).

Article ADS CAS PubMed Google Scholar

McGilligan, J. P., Griffin, P. F., Riis, E. & Arnold, A. S. Phase-space properties of magneto-optical traps utilising micro-fabricated gratings. Opt. Express 23, 8948–8959 (2015).

Article ADS CAS PubMed Google Scholar

Butts, D. L., Kinast, J. M., Timmons, B. P. & Stoner, R. E. Light pulse atom interferometry at short interrogation times. J. Opt. Soc. Am. B 28, 416–421 (2011).

Article ADS CAS Google Scholar

Soh, D. B. S., Biedermann, G., Lee, J. & Schwindt, P. Modeling of atom interferometer accelerometer. SAND Rep. 2020, 10087 (2020).

Google Scholar

Schwindt, P. Magnetic traps and guides for bose-einstein condensates on an atom chip: progress toward a coherent atom waveguide beamsplitter. Ph.D. thesis, University of Colorado (2003).

McGilligan, J. P., Griffin, P. F., Riis, E. & Arnold, A. S. Diffraction-grating characterization for cold-atom experiments. J. Opt. Soc. Am. B 33, 1271–1277 (2016).

Article ADS CAS Google Scholar

Cotter, J. P. et al. Design and fabrication of diffractive atom chips for laser cooling and trapping. Appl. Phys. B 122, 172 (2016).

Peters, A. High precision gravity measurements using atom interferometry. Ph.D. thesis, Stanford University (1998).

Download references

This work was supported by the Laboratory Directed Research and Development program at Sandia National Laboratories. We thank Daniel Soh, Connor Brasher, Joseph Berg, Tony G. Smith, Greg Hoth, Bethany Little, Dennis J. De Smet, Melissa Revelle, Andrew L. Starbuck, Christina Dallo, Andrew T. Pomerene, Douglas Trotter, Christopher T. DeRose, Erik J. Skogen, Allen Vawter, Matt Eichenfield, Aleem Siddiqui, Peter Rakich, and Shayan Mookherjea for their support and helpful discussion. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. This paper describes objective technical results and analysis. Any subjective views or opinions that might be expressed in the paper do not necessarily represent the views of the U.S. Department of Energy or the United States Government.

Sandia National Laboratories, Albuquerque, NM, 87185, USA

Jongmin Lee, Roger Ding, Justin Christensen, Randy R. Rosenthal, Aaron Ison, Daniel P. Gillund, David Bossert, Kyle H. Fuerschbach, William Kindel, Patrick S. Finnegan, Joel R. Wendt, Michael Gehl, Ashok Kodigala, Hayden McGuinness, Charles A. Walker, Shanalyn A. Kemme, Anthony Lentine & Peter D. D. Schwindt

Department of Physics and Astronomy, University of Oklahoma, Norman, OK, 73019, USA

Grant Biedermann

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

J.L. and R.D. designed the LPAI experiments. J.L., R.D., and J.C. carried out the LPAI experiments. J. L., R.D., and P.D.D.S. analyzed the results. J.C., R.R.R., H.M., and G.B. supported the experiment. A.I., D.P.G., D.B., K.H.F., C.A.W., G.B., and J.L. developed the compact sensor head with the GMOT. J.L., P.S.F., J.R.W., W.K., and S.A.K. designed, fabricated, and tested the microfabricated grating-chip. A.L., M.G., A.K., G.B., and J.L. investigated the PIC laser architecture. J.L., R.D, and P.D.D.S prepared the manuscript for publication. P.D.D.S and J.L. coordinated the project.

Correspondence to Jongmin Lee.

The authors declare no competing interests.

Nature Communications thanks Michael Holynski and the other, anonymous, reviewer(s) for their contribution to the peer review of this work.

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

Lee, J., Ding, R., Christensen, J. et al. A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system. Nat Commun 13, 5131 (2022). https://doi.org/10.1038/s41467-022-31410-4

Download citation

Received: 20 July 2021

Accepted: 15 June 2022

Published: 01 September 2022

DOI: https://doi.org/10.1038/s41467-022-31410-4

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Nature Communications (2023)

Nature Communications (2023)

Nature Communications (2023)

SHARE